31 research outputs found

    Review of research on smart tourism at home and abroad

    Get PDF
    Smart tourism not only is highly valued by the academic circles, but also has begun to practice in some areas and obtained good achievements. This article first expounds the origin of smart tourism; then discuss the current research progress and shortcomings of smart tourism from the conceptual connection, theory foundation and research methods, construction framework, technical support, application and evaluation system, etc. according to the content of the literature; at last, summarizes the theory structure of smart tourism research, revalue the position of smart tourism and propose some advice for future development

    Research of Simulation in Character Animation Based on Physics Engine

    Get PDF
    Computer 3D character animation essentially is a product, which is combined with computer graphics and robotics, physics, mathematics, and the arts. It is based on computer hardware and graphics algorithms and related sciences rapidly developed new technologies. At present, the mainstream character animation technology is based on the artificial production of key technologies and capture frames based on the motion capture device technology. 3D character animation is widely used not only in the production of film, animation, and other commercial areas but also in virtual reality, computer-aided education, flight simulation, engineering simulation, military simulation, and other fields. In this paper, we try to study physics based character animation to solve these problems such as poor real-time interaction that appears in the character, low utilization rate, and complex production. The paper deeply studied the kinematics, dynamics technology, and production technology based on the motion data. At the same time, it analyzed ODE, PhysX, Bullet, and other variety of mainstream physics engines and studied OBB hierarchy bounding box tree, AABB hierarchical tree, and other collision detection algorithms. Finally, character animation based on ODE is implemented, which is simulation of the motion and collision process of a tricycle

    Exploring Impaired SERCA Pump-Caused Alternation Occurrence in Ischemia

    Get PDF
    Impaired sarcoplasmic reticulum (SR) calcium transport ATPase (SERCA) gives rise to Ca(2+) alternans and changes of the Ca2+release amount. These changes in Ca(2+) release amount can reveal the mechanism underlying how the interaction between Ca(2+) release and Ca(2+) uptake induces Ca(2+) alternans. This study of alternans by calculating the values of Ca(2+) release properties with impaired SERCA has not been explored before. Here, we induced Ca(2+) alternans by using an impaired SERCA pump under ischemic conditions. The results showed that the recruitment and refractoriness of the Ca(2+) release increased as Ca(2+) alternans occurred. This indicates triggering Ca waves. As the propagation of Ca waves is linked to the occurrence of Ca(2+) alternans, the "threshold" for Ca waves reflects the key factor in Ca(2+) alternans development, and it is still controversial nowadays. We proposed the ratio between the diastolic network SR (NSR) Ca content (Cansr) and the cytoplasmic Ca content (Ca i ) (Cansr/Ca i ) as the "threshold" of Ca waves and Ca(2+) alternans. Diastolic Cansr, Ca i , and their ratio were recorded at the onset of Ca(2+) alternans. Compared with certain Cansr and Ca i , the "threshold" of the ratio can better explain the comprehensive effects of the Ca(2+) release and the Ca(2+) uptake on Ca(2+) alternans onset. In addition, these ratios are related with the function of SERCA pumps, which vary with different ischemic conditions. Thus, values of these ratios could be used to differentiate Ca(2+) alternans from different ischemic cases. This agrees with some experimental results. Therefore, the certain value of diastolic Cansr/Ca i can be the better "threshold" for Ca waves and Ca(2+) alternans

    Face Recognition with Facial Occlusion Based on Local Cycle Graph Structure Operator

    Get PDF
    Facial occlusion is a difficulty in the field of face recognition. The lack of features caused by occlusion may reduce the face recognition rate greatly. How to extract the identified features from the occluded faces has a profound effect on face recognition. This chapter presents a Local Cycle Graph Structure (LCGS) operator, which makes full use of the information of the pixels around the target pixel with its neighborhood of 3 × 3. Thus, the recognition with the extracted features is more efficient. We apply the extreme learning machine (ELM) classifier to train and test the features extracted by LCGS algorithm. In the experiment, we use the olivetti research laboratory (ORL) database to simulate occlusion randomly and use the AR database for physical occlusion. Physical coverings include scarves and sunglasses. Experimental results demonstrate that our algorithm yields a state-of-the-art performance

    Reliable Detection of Myocardial Ischemia Using Machine Learning Based on Temporal-Spatial Characteristics of Electrocardiogram and Vectorcardiogram

    Get PDF
    Background: Myocardial ischemia is a common early symptom of cardiovascular disease (CVD). Reliable detection of myocardial ischemia using computer-aided analysis of electrocardiograms (ECG) provides an important reference for early diagnosis of CVD. The vectorcardiogram (VCG) could improve the performance of ECG-based myocardial ischemia detection by affording temporal-spatial characteristics related to myocardial ischemia and capturing subtle changes in ST-T segment in continuous cardiac cycles. We aim to investigate if the combination of ECG and VCG could improve the performance of machine learning algorithms in automatic myocardial ischemia detection. Methods: The ST-T segments of 20-second, 12-lead ECGs, and VCGs were extracted from 377 patients with myocardial ischemia and 52 healthy controls. Then, sample entropy (SampEn, of 12 ECG leads and of three VCG leads), spatial heterogeneity index (SHI, of VCG) and temporal heterogeneity index (THI, of VCG) are calculated. Using a grid search, four SampEn and two features are selected as input signal features for ECG-only and VCG-only models based on support vector machine (SVM), respectively. Similarly, three features (S ( I ), THI, and SHI, where S ( I ) is the SampEn of lead I) are further selected for the ECG + VCG model. 5-fold cross validation was used to assess the performance of ECG-only, VCG-only, and ECG + VCG models. To fully evaluate the algorithmic generalization ability, the model with the best performance was selected and tested on a third independent dataset of 148 patients with myocardial ischemia and 52 healthy controls. Results: The ECG + VCG model with three features (S ( I ),THI, and SHI) yields better classifying results than ECG-only and VCG-only models with the average accuracy of 0.903, sensitivity of 0.903, specificity of 0.905, F1 score of 0.942, and AUC of 0.904, which shows better performance with fewer features compared with existing works. On the third independent dataset, the testing showed an AUC of 0.814. Conclusion: The SVM algorithm based on the ECG + VCG model could reliably detect myocardial ischemia, providing a potential tool to assist cardiologists in the early diagnosis of CVD in routine screening during primary care services

    Consistency in Geometry Among Coronary Atherosclerotic Plaques Extracted From Computed Tomography Angiography

    Get PDF
    Background: The three-dimensional (3D) geometry of coronary atherosclerotic plaques is associated with plaque growth and the occurrence of coronary artery disease. However, there is a lack of studies on the 3D geometric properties of coronary plaques. We aim to investigate if coronary plaques of different sizes are consistent in geometric properties.Methods: Nineteen cases with symptomatic stenosis caused by atherosclerotic plaques in the left coronary artery were included. Based on attenuation values on computed tomography angiography images, coronary atherosclerotic plaques and calcifications were identified, 3D reconstructed, and manually revised. Multidimensional geometric parameters were measured on the 3D models of plaques and calcifications. Linear and non-linear (i.e., power function) fittings were used to investigate the relationship between multidimensional geometric parameters (length, surface area, volume, etc.). Pearson correlation coefficient (r), R-squared, and p-values were used to evaluate the significance of the relationship. The analysis was performed based on cases and plaques, respectively. Significant linear relationship was defined as R-squared > 0.25 and p < 0.05.Results: In total, 49 atherosclerotic plaques and 56 calcifications were extracted. In the case-based analysis, significant linear relationships were found between number of plaques and number of calcifications (r = 0.650, p = 0.003) as well as total volume of plaques (r = 0.538, p = 0.018), between number of calcifications and total volume of plaques (r = 0.703, p = 0.001) as well as total volume of calcification (r = 0.646, p = 0.003), and between the total volumes of plaques and calcifications (r = 0.872, p < 0.001). In plaque-based analysis, the power function showed higher R-squared values than the linear function in fitting the relationships of multidimensional geometric parameters. Two presumptions of plaque geometry in different growth stages were proposed with simplified geometric models developed. In the proposed models, the exponents in the power functions of geometric parameters were in accordance with the fitted values.Conclusion: In patients with coronary artery disease, coronary plaques and calcifications are positively related in number and volume. Different coronary plaques are consistent in the relationship between geometry parameters in different dimensions
    corecore